Repository logo
  • Log In
Repository logo
  • Log In
  1. Home
  2. NIE Publications & Research Output
  3. Electronic Academic Papers
  4. Conference Papers
  5. PMT-scintillator system set up for D-D neutron TOF measurements in INTI plasma focus device
 
  • Details
Options

PMT-scintillator system set up for D-D neutron TOF measurements in INTI plasma focus device

URI
https://hdl.handle.net/10497/18684
Loading...
Thumbnail Image
Type
Conference Paper
Files
 AIP-1824-1-030028.pdf (887.94 KB)
Citation
Damideh, V., Saw, S. H., Sadighzadeh, A., Jalil Ali, Rawat, R. S., Lee, P., & Lee, S. (2017). PMT-scintillator system set up for D-D neutron TOF measurements in INTI plasma focus device. AIP Conference Proceedings, 1824(1), Article 030028. https://doi.org/10.14221/ajte.2017v42n2.3
Author
Damideh, Vahid
•
Saw, Sor Heoh
•
Sadighzadeh, Asghar
•
Jalil Ali
•
Rawat, Rajdeep Singh 
•
Lee, Paul Choon Keat 
•
Lee, Sing
Abstract
This paper summarizes a Photomultiplier-Scintillator diagnostic system for use in our plasma focus experiments at the Center for Plasma Research INTI IU. The system features an anode-grounded high pulse linearity voltage divider and uses NE102A plastic scintillators. It has detected D-D neutrons in INTI plasma focus device with clear and high signal to noise ratio. Neutron TOF of 120 ns has been measured from the time difference between hard x-ray pulse peak and neutron peak time over a flight path of 2.6±0.01 m; giving energy of 2.5±0.1 MeV for these side-on neutrons.
Keywords
  • Photomultiplier

  • Scintillator

  • Neutron

  • Time of Fight

  • Plasma Focus

Date Issued
2017
DOI
10.14221/ajte.2017v42n2.3
  • Contact US
  • Terms of Use
  • Privacy Policy

NTU Reg No: 200604393R. Copyright National Institute of Education, Nanyang Technological University (NIE NTU), Singapore

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science