Repository logo
  • Log In
Repository logo
  • Log In
  1. Home
  2. NIE Publications & Research Output
  3. Electronic Academic Papers
  4. Journal Articles
  5. Validation of the Perception Neuron system for full-body motion capture
 
  • Details
Options

Validation of the Perception Neuron system for full-body motion capture

URI
https://hdl.handle.net/10497/23698
Loading...
Thumbnail Image
Type
Article
Files
 PLoS-17-1-e0262730.pdf (1.05 MB)
Citation
Choo, C. Z. Y., Chow, J. Y., & Komar, J. (2022). Validation of the Perception Neuron system for full-body motion capture. PLOS ONE, 17(1), Article e0262730. https://doi.org/10.1371/journal.pone.0262730
Author
Choo, Corliss Zhi Yi
•
Chow, Jia Yi 
•
Komar, John 
Abstract
Recent advancements in Inertial Measurement Units (IMUs) offers the possibility of its use as a cost effective and portable alternative to traditional optoelectronic motion capture systems in analyzing biomechanical performance. One such commercially available IMU is the Perception Neuron motion capture system (PNS). The accuracy of the PNS had been tested and was reported to be a valid method for assessing the upper body range of motion to within 5° RMSE. However, testing of the PNS was limited to upper body motion involving functional movement within a single plane. Therefore, the purpose of this study is to further validate the Perception Neuron system with reference to a conventional optoelectronic motion capture system (VICON) through the use of dynamic movements (e.g., walking, jogging and a multi-articular sports movement with object manipulation) and to determine its feasibility through full-body kinematic analysis. Validation was evaluated using Pearson’s R correlation, RMSE and Bland-Altman estimates. Present findings suggest that the PNS performed well against the VICON motion analysis system with most joint angles reporting a RMSE of < 4° and strong average Pearson’s R correlation of 0.85, with the exception of the shoulder abduction/adduction where RMSE was larger and Pearson’s R correlation at a moderate level. Bland-Altman analysis revealed that most joint angles across the different movements had a mean bias of less than 10°, except for the shoulder abduction/adduction and elbow flexion/extension measurements. It was concluded that the PNS may not be the best substitute for traditional motion analysis technology if there is a need to replicate raw joint angles. However, there was adequate sensitivity to measure changes in joint angles and would be suitable when normalized joint angles are compared and the focus of analysis is to identify changes in movement patterns.
Date Issued
2022
Publisher
Public Library of Science
Journal
PLoS ONE
DOI
10.1371/journal.pone.0262730
Dataset
https://doi.org/10.25340/R4/IZKYZR
  • Contact US
  • Terms of Use
  • Privacy Policy

NTU Reg No: 200604393R. Copyright National Institute of Education, Nanyang Technological University (NIE NTU), Singapore

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science